ISDN-TRK (DS1 ISDN Trunk)
Issue 5 October 2002
1327
555-233-119
1019
ABORT
Another Test call is in progress.
1. Issue the list isdn-testcall command to locate the test call.
2. Issue the status isdn-testcall command to find out the duration and
start time of the test call.
3. Issue the clear isdn-testcall command to stop the test call from
running.
1020
ABORT
There is a problem with DS1 Interface Circuit Pack.
1. Refer to the DS1-BD (DS1 Trunk circuit pack).
1024
ABORT
Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the
Maintenance/Test circuit pack.
2. Retry the test.
1113
ABORT
The signaling link has failed. Therefore, the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #255 (Signaling Link State Check Test).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116
ABORT
The switch could not appropriately change the ISDN service state.
1. Determine if a call is active on this DS1 ISDN Trunk (use the status
trunk
2. If not, check the Error and Alarm Logs for problems with this
ISDN-TRK (DS1 ISDN Trunk) MO.
1117
ABORT
ISDN B-channel maintenance message is already outstanding.
1. Wait two minutes. Then try again.
1118
ABORT
Far-end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Issue the status trunk
3. Try the test again.
1119
ABORT
The test call was aborted due to a normal call attempt on this trunk. The
test call is performed only if the trunk is idle.
1. Either wait for the normal call to terminate normally, or force it to be
dropped by using the busyout trunk
Table 324.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page