Maintenance Objects
555-233-119
738
Issue 5 October 2002
1020
ABORT
TN230x circuit-pack problem
1. See the
‘‘ATM-INTF (TN2305/6)’’
maintenance object.
1024
ABORT
Maintenance/Test Digital Port in use
1. Wait until yellow and green LEDs on the Maintenance/Test circuit pack
are OFF.
2. Rerun the test.
3. If the problem persists, see the M/T-DIG (Maintenance/Test Digital Port)
maintenance object.
1113
ABORT
Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check Test).
1116
ABORT
Switch could not change the service state
1. See if calls are active. Run status trunk grp#/mbr#.
2. If a call is active, proceed as for Error Code 1119.
3. If a call is not active, check the Error and Alarm Logs and refer to the
ATM-TRK (Circuit Emulation Service Circuit Pack) maintenance object.
1117
ABORT
ISDN service message outstanding
1. Wait 2 minutes and try again.
1118
ABORT
Far-end not administered
1. Check the administration of the far-end of the ATM trunk. Run status
trunk grp#/mbr#.
2. Try the test again.
1119
ABORT
Test call aborted, normal call attempted
1. Wait for the call to terminate normally or drop it by running busyout
trunk grp#/mbr#.
2. When the trunk is idle, retry the test.
1120
ABORT
Trunk OUT-OF-SERVICE/FAR-END
1. Try to change the service state via Test #256 (Service State Audit Test).
2. Try the test again.
1122
ABORT
No test-line number for the far-end switch
1. Check the Trunk Group Administration form.
1123
ABORT
No Feature Access Code administration for this Facility Test
1. Check the Dial Plan and Feature Administration forms.
Table 75. TEST #258 ISDN Test Call —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page