Maintenance Objects
555-233-119
674
Issue 5 October 2002
PASS
The station is connected properly to the switch. This test may also pass if
no terminal equipment is connected and the terminal is located far from the
switch (that is, it is off-premises). User-reported troubles on this port should
be investigated by using other port tests, by examining station wiring, by
examining the station, and by ensuring that the terminal is correctly
translated as off-premises or on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between
the internal ID and the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 49. TEST #48 Station Present Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page