set options
Issue 5 October 2002
405
555-233-119
set options
Use set options to enable a remote user with INADS permission to select which
types of maintenance categories report alarms automatically and which types
require customer call-in. Correct options settings can reduce the number of
ineffective alarms to the TSC. For effective results, use the set options default
settings specified in this section. Technicians should not change these settings.
Special circumstances (for example, special studies) may require temporary
changes under the guidance of Tiers 3 and 4.
NOTE:
Alarms do not upgrade.
Form Input
The following example is a display of set options.
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature Interactions
set options
none
init
inads
see
below
none
set options Page 1 of 8
ALARM REPORTING OPTIONS
Major Minor
On-board Station Alarms: w w
Off-board Station Alarms: w w
On-board Trunk Alarms (Alarm Group 1): y y
Off-board Trunk Alarms (Alarm Group 1): w w
On-board Trunk Alarms (Alarm Group 2): w w
Off-board Trunk Alarms (Alarm Group 2): w w
On-board Trunk Alarms (Alarm Group 3): w w
Off-board Trunk Alarms (Alarm Group 3): w w
On-board Trunk Alarms (Alarm Group 4): w w
Off-board Trunk Alarms (Alarm Group 4): w w
On-boar Adjunct Alarms: w w
Off-board Alarms: w w
Off-board DS1 Alarms: w
w
Off-board PI-LINK Alarms: w w
Off-board Alarms (Other): w w
Memory Card Capacity Alarms: y