BRI-SET, ASAI-ADJ, BRI-DAT
Issue 5 October 2002
823
555-233-119
The switch sent a message to the endpoint which did not respond in the
allotted time. This can happen occasionally due to failure of the
point-to-point signaling link or because of a problem in the BRI endpoint or
ASAI adjunct or adjunct. Use test station extension sh and look at the
results of the BRI Layer 3 Query Test (#629). If this test fails, follow the
repair procedure for Test #629.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, replace or
reinsert the circuit pack.
c. This error occurs when the endpoint does not respond to the service state
query message sent to the adjunct or the endpoint. This error causes an
alarm to be raised. The alarm is retired when the switch receives a
response to the service state query to the endpoint or the adjunct.
For BRI endpoints, the Aux Data field for this error contains “0.” When it
occurs, use test station
extension
sh and look at the results of the BRI
Layer 3 Query Test (#629). If this test fails, follow the repair procedure for
Test #629.
Table 120.
Error Type 2 Cause Values
Aux Data
Timer Type
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer 2 Failure timer)
16
TM100 (Management Information Message timer 1)
17
TM200 (Management Information Message timer 2)
102
TASAI (ASAI Routing Timer)
Continued on next page