display system-parameters maintenance
Issue 5 October 2002
251
555-233-119
Output
The following example shows the output for display system-parameters
maintenance.
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
display
system-
parameters
maintenance
schedule
Report sent to printer
Use the screen to schedule
execution of the command. The
command is placed in the
command queue and is executed
at the specified time. The
information displayed by the
command is sent to the system
printer instead of the screen.
1
Examples:
display system-parameters
maintenance
display system-parameters
maintenance print
display system-parameters
maintenance schedule
1
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
super-user
Maintain
Switch
Circuit
Packs
permissions
none
none
display system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Telephone Number: 5551212 Abbrev Alarm Report? y
Second OSS Telephone Number: 5551213 Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y
Restart Notification? y
Test Remote Access Port? n
CPE Alarm Activation Level: none
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 22: 00 Stop Time: 04: 00
Daily Maintenance: daily Save Translation: daily
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no EXP-LINK Interchange: no