Maintenance Commands
555-233-119
588
Issue 5 October 2002
test station
Use test station to run hardware diagnostic tests on a port circuit assigned to the
extension. The technician must specify the extension and a translation is
automatically done to the physical port location.
!
WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test station
extension
short
long
repeat
number
clear
schedule
The station extension (must conform to
dial-plan)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Use the screen to schedule execution
of the command. The command is
placed in the command queue and is
executed at the specified time. The
information displayed by the command
is sent to the system printer instead of
the screen.
2
Examples:
test station 81709 l
test station 85136 s r 2
test station 85036 l r 25
test station 85036 l r 25 schedule
test station 84297 r 4
test station 81709 c
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
nms
Test
Sequence
= short;
Repeat =
1
none