BRI-SET, ASAI-ADJ, BRI-DAT
Issue 5 October 2002
835
555-233-119
1187
ABORT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, release the station with
release station.
a. If this error type is present for BRI-PORT and BRI-SET, release the
port with release port PCSSpp and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, release
the circuit pack with release port PCSSpp and run the test again.
If the error is present for both BRI-BD and BRI-PORT, release the
circuit pack with release board PPCSS and run the test again.
If the error is present for BRI-SET only, release the circuit pack with
release port PPCSS and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2068
ABORT
The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Loop Back Testing.
1. Use change station extension and set the
MIMs Supported
field
to n.
2069
ABORT
The endpoint has returned an error response to the application message
sent by the switch.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 126.
TEST #627 BRI Remote Loop Back —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page