display alarms
Issue 5 October 2002
203
555-233-119
Feature Interactions
If the user disables the alarm origination with change system-parameters
maintenance, the Ack field on the Alarm Report is blank regardless of the true
acknowledged state of the alarm.
Options screen
When you enter display alarms, an options screen appears. Select the options
you want to view on the report. The figure below is an example of the options
screen for Alarm Reports.
Field descriptions
ALARM TYPES
Enter y or n in any of the 5 alarm type fields
Interval
Enter one of the codes below:
m = last month
h = last hour
d = last day
w = last week
a = all
From
Month/day/year (example: 01/01/97).
If blank, the report contains all the active alarms for the month prior to
the current date.
To
Month/day/year (example: 01/15/97).
If blank, the report contains all the active alarms starting with the
From
date to the current date.
Cabinet
Administered cabinet number (1-3)
Port Network
1-3
display alarms Page 1 of 1
ALARM REPORTS
The following options control which alarms will be displayed.
ALARM TYPES
Active? y_ Resolved? n_
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: ____
Port Network: __
Board Number: _______
Port: ________
Category: ________
Extension: _____
Trunk ( group/member ): ___/___