Maintenance Commands
555-233-119
254
Issue 5 October 2002
Restart Notification
Enables the system to originate a call to the OSS and report
any system restarts caused by problems with the system.
Suspension Threshold
The threshold for suspending Cleared Alarm Notification (1-15).
Some problems may cause alarms to be generated and then
resolved repeatedly. To detect these problems (by not sending
additional Cleared Alarm notifications to indicate a problem-
free system), the system suspends Cleared Alarm Notification
when it has reported this administrable number of Cleared
Alarm notifications in a 24-hour period. A suspended Cleared
Alarm Notification is only enabled again with a successfully
completed “logoff” command, a system reset, or when the
threshold is changed. This field is irrelevant if Cleared Alarm
Notification or Alarm Origination is disabled.
Test Remote Access
Port
Specifies whether testing of the remote access port on the
SYSAM circuit pack is enabled. Enter y when an INADS line is
connected to the system and there is a maintenance contract in
effect, so that alarm origination capability is maintained.
CPE Alarm Activation
Level
Indicates the minimum level (Major, Minor or Warning) at which
the Customer-Provided Equipment (CPE) alarm is activated. If
the level is none, the CPE is not activated for any alarm.
Default is none.
NOTE:
The CPE alarm is always activated when the system
goes into Emergency Transfer, regardless of the CPE
Alarm Activation Level setting.
Customer Access to
INADS Port
Provides the capability to prohibit access to system
administration and maintenance interface, via the INADS port
when using customer login ID’s. This field can only be activated
by Avaya services through system-parameters maintenance
administration. Default is n.
Repeat Dial Interval
(MMS)
Indicates the number of minutes that the system must wait
before attempting another call origination to an OSS. This timer
is triggered by the lack of a far-end acknowledgment. Default is
7.