Maintenance Objects
555-233-119
622
Issue 5 October 2002
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack combination operating in control-link (CL) mode. For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. Port-level
maintenance is covered by ADX16A-PT.
EMBEDDED AUDIX consists of 2 circuit packs that occupy 4 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log)
Alarm Level
Initial Command To
Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.).
Full Name of MO
ADXCL-BD or
\ADX16A-BD
MINOR, or WARNINGS
test board PCSS sh
AUDIX Circuit Pack