Maintenance Objects
555-233-119
888
Issue 5 October 2002
Packet Interface Test (#598)
This non-destructive test checks the packet bus interface circuitry on the CLAN
circuit pack. Test failure indicates faulty circuit pack.
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine if the
CLAN circuit pack is congested.
Normal call handling resumes when the CLAN circuit pack has recovered from
congestion.
Table 147.
TEST #598 Packet Interface Test
Error
Code
Test
Result
Description/ Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
FAIL
Circuit pack has detected a failure of the Packet Interface Test (#598).
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test continues to fail, replace the circuit pack.
PASS
The Packet Interface Test (#598) passed.
Continued on next page
If:
Then:
Used buffers are, or are nearly,
exhausted,
The test fails
The test fails,
The switch redirects outgoing calls to another
available CLAN, and denies new incoming calls