Maintenance Objects
1598
Issue 5 October 2002
Figure 50.
Synchronization Timing Loop
A correctly designed network has no loops and each piece of equipment in the
network is supplied by a clock of equal or lower stratum (that is, the inputs to a
Stratum 3 clock should NEVER be from a Stratum 4 device). It is strongly
recommended that the network administrator be consulted before
administering any synchronization changes.
Error Log Entries and Test to Clear Values
Table 460.
Synchronization Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test synchronization
1 (a)
1
Any
None
WARNING/
MINOR (j)
2
OFF
None
18 (b)
0
disable sync
WARNING
OFF
enable sync
257 (c)
1
Any
None
WARNING/
MINOR(j)
2
OFF
None
513 (d)
1
Any
None
WARNING/
MAJOR(j)
2
OFF
None
769 (e)
None
MAJOR/
WARNING
3
OFF
None
Continued on next page
Communications
system
Generic 2
Communications
system
Generic 2
Communications
system
Generic 1
Communications
system
Generic 1
Communications
system
Generic 1
Communications
system
Generic 1
Timing
loop
Correct
timing
distribution
r11n1p3 LJK 072501
Synchronization reference
(primary or secondary).