Maintenance Commands
555-233-119
582
Issue 5 October 2002
test processor
Use test processor to run hardware diagnostic tests on a processor circuit pack.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
processor
location
short
long
clear
schedule
Cabinet number (a)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
This option causes the test sequence
(short or long) to repeat until the
alarm (if any) is cleared or a single
test in the sequence fails.
1
Use the screen to schedule execution
of the command. The command is
placed in the command queue and is
executed at the specified time. The
information displayed by the
command is sent to the system printer
instead of the screen.
2
Examples:
test processor
test processor schedule
test processor a
test processor 1a
test processor a sh
test processor a l c
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
For SPE
simplex, the
location is
optional and
defaults to
cabinet 1,
carrier a.
Defaults for
the remaining
parameters
are short with
a repeat of 1.
none