DID-DS1 (DS1 DID Trunk)
Issue 5 October 2002
987
555-233-119
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57476, on-hook before wink; 57477, on-hook
before ready to receive digits; 57485, wink too short for valid signal.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
c. System Technician has busied out the trunk to out-of-service state. No calls
can be made on this trunk.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
18 (c)
WARNING
OFF
release trunk <grp>/mbr>
130 (d)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (e)
57474
57473
513 (f)
57392
None
MIN/MAJ
2
OFF
769 (g)
57393
None
MIN/MAJ
2
OFF
1281
Conference Circuit
Test (#7)
MAJ/MIN/
WRN
3
ON
test trunk <grp>/<mbr> l
1537
NPE Crosstalk
Test (#6)
MAJ/MIN/
WRN
3
ON
test trunk <grp>/<mbr> l
1793 (h)
ON
test board PCSS l
2305(i)
50944
None
MIN/MAJ
2
OFF
3840 (j)
Port Audit and
Update Test (#36)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this
trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Table 184.
DID-DS1 Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page