BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 5 October 2002
815
555-233-119
Electronic Power Feed Inquiry (#622)
This test queries the BRI-LINE circuit pack for the status of the Electronic Power
Feed (EPF) supplied to a BRI endpoint or an ASAI or adjunct. If the EPF is on and
no overcurrent condition exists, this test passes. All other states are not normal
and indicate a problem with the endpoint or adjunct, the wiring to the endpoint or
adjunct, or the BRI-LINE circuit pack. This test is not run on the TN2208 circuit
pack or the TN2198 and will always return a pass for a TN2198. The TN2208 has
no power feeds.
Table 115.
TEST #622 Electronic Power Feed Inquiry
Error
Code
Test
Result
Description/ Recommendation
1005
ABORT
This test is not valid for this port type. Ports on the TN2208 cannot run
this test because this board does not have an electronic power feed.
2000
ABORT
Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack with busyout board PCSS and reset board PCSS.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1
FAIL
The BRI-LINE circuit pack reports that it has detected an overcurrent
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the circuit pack
and the endpoint or adjunct. Check the endpoints and replace one
or both sets if the sets are drawing too much current. Use test port
PCSSpp and review the results of the EPF Inquiry Test to verify the
repair. If this test is still fails, go to Step 2.
2. Use test port PCSSpp, and review the results of the Level 1 Status
Inquiry Test. If this test is also failing, follow the repair procedure for
the Level 1 Status Inquiry Test.
2000
ABORT
Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack with busyout board PCSS and reset board PCSS.
2. If the test aborts again, replace the circuit pack.
PASS
The Electronic Power Feed Inquiry Test reports that the EPF is on.
Continued on next page