555-233-119
978
Issue 5 October 2002
Error Log Entries and Test to Clear Value
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. This error is logged when the Data Line circuit pack finds an error with the
transmit/receive circuitry of an administered Data Line on circuit pack
insertion. Perform the following procedure:
1. Issue the busyout board PCSS command to busyout the Data Line
circuit pack on which this port resides.
2. Issue the reset board PCSS command. Check the Hardware Error
Log to determine if Error Type 769 is logged again for the DAT-LINE
MO.
NOTE:
When displaying errors, set the
Active Alarms Only
field
to n.
If Error Type 769 reappears, replace the DAT-LINE circuit pack. If
Error Type 769 does not reappear, proceed to Step 3.
3. Issue the release board PCSS command to release the Data Line
circuit pack on which this port resides.
Table 179.
Data Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1
Digital Loop Around
Test (#171)
MINOR
ON
test port PCSSpp sh r 2
15(a)
Any
Audit Update Test
(#36)
18
0
busyout port PCSSpp
WARNING
OFF
release port PCSSpp
130(b)
None
WARNING
ON
test port PCSSpp sh
257
Conference Circuit
Test (#7)
MINOR
ON
test port PCSSpp l r 2
513
NPE Crosstalk Test
(#6)
MINOR
ON
test port PCSSpp l r 2
769(a)
Any(c)
None