ADX16D-B (16 Port AUDIX Circuit Pack)
Issue 5 October 2002
621
555-233-119
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. Port-level
maintenance is covered by ADX16D-PT.
EMBEDDED AUDIX consists of 2 circuit packs that occupy 4 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy of its own that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
MO Name (in Alarm Log)
Alarm
Level
Initial Command To Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.).
Full Name of MO
ADX16D-B
MINOR
test board PCSS sh
AUDIX Circuit Pack
ADX16D-B
WARNI NG
test board PCSS sh
AUDIX Circuit Pack