Maintenance Objects
555-233-119
778
Issue 5 October 2002
Aux Data YY
7
Transmit Network Processor failed
8
Memory read failed
9
Dual UART chip failed
10
LANHO receive parity error
11
LANHO FIFO over flow error
12
LAN bus time out.
13
LANHO Xmit FIFO overflow error
14
One or more on-board DSPs failed
Table 102.
Aux Data YY for ATM Board Error Query Test (#1259)
If YY=
Then
15
Back plane clock failed
16
Loss of signal
17
Loss of frame
18
MS alarm indication signal error
19
MS remote defect indicator error
20
Loss of Pointer
21
Path Signal Level mismatch
22
High-level Path alarm indication signal
23
High-level Path remote defect indicator
24
Loss of Cell Delineation
25
Uncorrectable headers sent by the ATM switch.
26
Too many cells with invalid VPI/VCI combination.
27
The signalling link between the board and the ATM switch is down.
34
AAL5 Excessive retransmission requests -per VC
Continued on next page
Table 101.
Aux Data XX for ATM Board Error Query Test (#1259)
—
Continued
If XX=
Then
Continued on next page