status pri-endpoint
Issue 5 October 2002
497
555-233-119
status pri-endpoint
Use status pri-endpoint to display internal software state information for
diagnosis, and to help locate facilities with which a PRI endpoint is
communicating. Status information for each of the B-channels making up the PRI
endpoint display in addition to some overall PRI endpoint information.
Output
The following example shows the output for the status pri-endpoint 22501
command and assumes the following:
■
PRI endpoint ports for extension 22501 are in cabinet 1, carrier B, slot 20,
circuit 1 to 6.
■
The ports 1 to 3 of the specified PRI endpoint are connected on an active
call to ports 13 to 15 of board in location 1B19 (cabinet 1, carrier B, slot 19).
■
Ports 4 and 5 of the specified PRI endpoint are idle.
■
Port 6 of the specified PRI endpoint is out of service, and background
maintenance testing is being performed on the port.
NOTE:
A PRI endpoint can initiate and receive a call on any one or more of the
B-channels making up the PRI endpoint.
Action/Object
Qualifier
Qualifier Description
Logins
Default
Feature Interactions
status
pri-endpoint
extension
PRI endpoint extension to be
displayed (see dial-plan).
Report sent to printer
Examples:
status pri-endpoint 25012
status pri-endpoint 77868
status pri-endpoint 66078 print
init
inads
craft
nms
browse
none
none
status pri-endpoint 22501 page 1 of 1
PRI-ENDPOINT STATUS
Extension: 22501 Width: 6
Signaling Group ID: 3 B-Channels Active: 3
Originating Auto Restoration? n B-Channels Idle: 2
Port Service State Test In Progress Connected Port
01B2001 in-service/active n 01B1913
01B2002 in-service/active n 01B1914
01B2003 in-service/active n 01B1915
01B2004 in-service/idle n
01B2005 in-service/idle n
01B2006 out-of-service-NE y