UDS1-BD (UDS1 Interface Circuit Pack)
Issue 5 October 2002
1783
555-233-119
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or ports of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the reset board command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Therefore,
it cannot be reset without major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another UDS1 Interface circuit pack or to the Tone-Clock circuit
pack via the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
2000
ABORT
Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the maintenance
strategy recommended for this error type.
2012
ABORT
Internal system error
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the reset board command at 1-minute intervals for a maximum of
5 times.
FAIL
The UDS1 Interface circuit pack failed in the Internal Looparound Test.
If the UDS1 connects to a T1 network facility or another switch:
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
2. Enter the list measurement ds1-log UUCSS command to read the error
seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using the
same signaling mode, framing mode, and line coding.
4. Check the physical connectivity of DS1 Interface circuit packs and cable.
5. Replace the local UDS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1 endpoint.