ETH-PT (Control LAN Ethernet)
Issue 5 October 2002
1167
555-233-119
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 1: Ethernet Local Looparound Test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
b. Error Type 513: Link Integrity Inquiry Test (#1282) failed or CLAN port
detected loss of Ethernet link integrity.
Possible causes:
■
Cabling
■
Ethernet transceiver
1. Test the port (test port UUCSSpp long).
2. If the Link Integrity Inquiry Test (#1282) fils, refer to its repair
procedure.
Table 255.
ETH-PT Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp s
1 (a)
0
Ethernet Local
Looparound
Test (#1278)
MINOR
ON
test port UUCSSpp l r 3
513 (b)
0
Link Integrity Inquiry
(#1282)
MINOR
OFF
test port UUCSSpp r 2
769 (c)
0
WNG
OFF
1281 (d)
0
1537, 1538
(e)
Session Status Test
(#1286)
MINOR
OFF
1793-1920
(f)
2305-2560
(g)
2561-2816
(g)
3329 (h)
TCP/IP Ping Test
(#1281)
WNG
OFF
Continued on next page