How to use the Maintenance book
Issue 5 October 2002
35
555-233-119
Screen 4.
Test Results screen
12. Find the Port Diagnostic Test number (35 in our example) in the DID-TRK
section of the Maintenance book. Note the
Error Code
(61472).
13. Look in
Table 3
for Test #35 and then find “61472” in the Error Code
column and “FAIL” in the Test Result column.
14. Read the Description/Recommendation column.
15. Perform the steps in the Description/Recommendation column.
16. Type test port 01C1008 long and press
Enter
to test the port again after
you complete all of the recommendations.
17. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
18. Type display alarms and press
Enter
twice.
19. Check that the DID-TRK alarm does not appear in the log.
Table 3.
TEST #35 Port Diagnostic Test
Error
Code
Test
Result
Description/Recommendation
61472
FAIL
Battery feed test failed. A problem with the incoming CO line was detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line is not the problem, the failure is on the DID port. Replace
the circuit pack.
Continued on next page
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1008 DID-TRK 35 FAIL 61472