Maintenance Objects
555-233-119
684
Issue 5 October 2002
1392
ABORT
This port is currently a TTI port and the test does not execute on it.
1. Verify that the port is a TTI port:
■
Use display port UUCSSpp. The display shows that the port is a
TTI port/
■
Use list configuration. The display shows a
t
for the port.
2. If both commands indicate that the port is a TTI port, the abort is
correct for the test, and no action is necessary.
3. If either command indicates that the port is
not
a TTI port, escalate the
problem.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The port’s battery feed chip is unable to supply sufficient power to the
terminal equipment. This test result might be marginal, and the terminal
equipment may be operating satisfactorily.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the circuit pack only if the
customer is experiencing problems.
PASS
The port’s battery feed chip is able to provide sufficient power to the station
equipment to detect on-/off-hook, but may not be able to supply power for
touch-tones.
1. If touch-tones are inoperative on this station, replace the circuit pack
because this port is inoperative.
2. Investigate user-reported troubles on this port by running other port
tests, by examining station wiring, or by inspecting the station.
Table 52. TEST #35 Battery Feed Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page