XXX-BD (Common Port Circuit Pack)
Issue 5 October 2002
1917
555-233-119
NPE Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
Table 579.
TEST #50 NPE Audit Test
Error
Code
Test Result
Description/ Recommendation
none or
2100
ABORT
System resources required for this test are not available.
1019
ABORT
Test already in progress.
FAIL
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The circuit pack’s NPEs have been updated with their translation.
EXTRA BD
Certain circuit packs have limitations on how many circuit packs can
be in the system such as the Call Classifier (TN744). The Call
Classifier allow only 10 circuit packs in each system. All additional
circuit packs return EXTRA-BD and should be removed.
any
NO BOARD
This is normal if the test is being done when (a) the circuit pack is
not physically in the system or (b) the system is booting up.
Otherwise, there is some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5
times.
Continued on next page