CLAN-BD (Control LAN Circuit Pack)
Issue 5 October 2002
881
555-233-119
q. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms may be present:
■
Circuit pack port tests return
NO BOARD
.
■
List configuration command shows circuit pack and ports are
installed properly
1. Busyout (busyout board UUCSS) and release (release board
UUCSS) circuit pack
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout
board UUCSS), reset (reset board UUCSS), and release (release
board UUCSS) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal
escalation procedures.
r. Error Type 3840: Circuit pack received bad control channel message from
switch.
Aux Data:
s. Error Type 3841-3843: errors do not affect service.
If Error Type 3999:
And traffic
volume is:
Then:
Does not accompany
Error Type 3586
Heavy
Circuit pack is in service, but sent at least half
hyperactive threshold. With heavy traffic, this is
normal.
Does not accompany
Error Type 3586
Light
Circuit pack is in service, but sent at least half
hyperactive threshold. With light traffic, this error
indicates a problem with the circuit pack, its links, or
the equipment attached to the links.
Accompanies
Error Type 3586
Either Light or
Heavy
Switch removed hyperactive circuit pack.
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
4102
Bad application identifier