MEDPRO (Media Processor MAPD Circuit Pack)
Issue 5 October 2002
1379
555-233-119
SAKI Sanity Test (#53)
This is a destructive test.
This test is only run as a part of a reset board procedure. For the Media
Processor, it is necessary to use the change ip-interfaces form to disable the
Media Processor IP interface before performing this reset board procedure. Other
common circuit packs can be reset with the reset board UUCSS command which
also executes this test.
A reset of this circuit pack will take about 3 1/2 minutes.
Table 353.
TEST #53 SAKI Sanity Test
Error
Code
Test
Result
Description/ Recommendation
None
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
1015
ABORT
Port is not out-of-service.
Busy out the circuit pack.
Execute command again.
2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
2803
ABORT
It is necessary to reset the board.
Use the change ip-interfaces form to disable the Media Processor IP
interface.
Execute the command again.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
Execute command again.
If the problem persists, replace the circuit pack.
Continued on next page