status journal-link
Issue 5 October 2002
489
555-233-119
status journal-link
Use status journal-link to display if the link is up or down. If the link is down, the
system displays the number of times the switch tries to initialize the link. A journal
printer documents automatic wake-up events, emergency access to attendant
events, and housekeeping events when the property management system is not
functional. A journal printer may also generate reports for automatic wake-up
events and emergency access events at a scheduled time. If system configuration
includes two printers, one is for housekeeping events only and the other is for
automatic wake-up events and emergency access events.
For general information on journal printer links, see
‘‘busyout journal-printer’’
.
Output
The following example shows the output from status journal-link wakeup-log.
Field descriptions
Action/Object
Qualifier
Qualifier Description
Logins
Default
Feature Interactions
status
journal-link
wakeup-
log
pms-log
printer that handles automatic
wakeup and emergency access to
attendant events and scheduled
reports.
printer that handles pms down
events.
Reports print to SAT-linked printer.
init
inads
craft
cust
rcust
bcms
browse
none
none
Link State
If extensions are administered in the System Parameters
Hospitality form, wakeup-logs or pms-log links are considered to
be administered only.
Maintenance Busy
Is maintenance testing performing on the link?
status journal-link wakeup-log
JOURNAL LINK STATUS
Link State: up
Maintenance Busy? no