Maintenance Objects
1546
Issue 5 October 2002
Notes:
a. Error Type: 1 - These are in-line errors and can only be resolved over time.
■
40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5th incoming call will cause an inline error from
the board.
■
40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal does not ring, then replace it. Otherwise, issue
the test port UUCSSpp command, and follow the procedure for
Test #48.
■
40977 indicates that terminal equipment was not connected when
ringing was attempted. Run the short test via the test port
UUCSSpp command, and follow the procedure for the results of
Test #48.
15(b)
Any
Audits and
Updates
Test (#36)
18
0
busy-out
station
extension
WRN
ON
release station
extension
257(c)
40973
none
513(d)
Station
Present Test
(#48)
WRN
OFF
test port UUCSSpp sh r 2
769
Battery Feed
Test (#35)
MIN/
WRN
2
ON
test port UUCSSpp sh r 2
2817(e)
Hyperactive
MINOR
OFF
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
Table 433.
Analog Line Error Log Entries
—
Continued
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page