Maintenance Objects
1378
Issue 5 October 2002
Control Channel Looparound Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
Table 352.
TEST #52 Control Channel Looparound Test
Error
Code
Test
Result
Description/ Recommendation
None
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is one of the Port
circuit packs, replace the circuit pack. Otherwise, if the circuit
pack is part of the SPE, use the procedure described in
Replacing SPE Circuit Packs in Chapter 5.
3. Retry the command a maximum of 5 times.
PASS
Communication with this circuit pack is successful.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the
MedPro interface if it is not already administered.
2. If the board was already administered correctly, check the error
log to determine whether the board is hyperactive. If this is the
case, the board is shut down. Reseating the board re-initializes
the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the
port.