CO-TRK (CO Trunk)
Issue 5 October 2002
917
555-233-119
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to Table 10-93 for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
1793
Loop Around and
Conference Test
(#33)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 3
2049
NPE Cross Talk
Test (#6)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 3
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone Test (#0)
MAJ/MIN/
WRN
2
OFF
test port PCSS l r 1
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone Test (#0)
MAJ/MIN/
WRN
2
OFF
test port PCSS l r 1
3585 (d)
57424
None
3840 (f)
8000
Analog
Transmission
(#844-848)
OFF
3841 (f)
Analog
Transmission
(#844-848)
MINOR
OFF
test analog testcall PCSS
pp r 2
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set-options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Table 159.
CO Trunk Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page