CO-DS1 (DS1 CO Trunk)
Issue 5 October 2002
913
555-233-119
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, an insane board is inserted, or the board is hyperactive (see Note
below).
1. Check to ensure that the board translations are correct. Use list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between
the internal ID and the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with the sequence
suggested above. If the ports are translated after issuing list config,
but the ’Vintage’ field reports that there is no board when there really
is a board, busyout board and release busy board will not work
even though the reset board works. The software puts the
hyperactive board back in service after the hyperactivity clears.
Table 158.
TEST #314 DS1CO Dial Tone Seizure Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page