Maintenance Objects
1520
Issue 5 October 2002
MTP Manager I Loop Around Test (#228)
This test is a nondestructive test. The test places the Manager I channel of the
MTP into a loop around mode, and it verifies the data integrity of the channel.
Although the test is nondestructive, it causes loss of keyboard input from the PPN
Manager I.
Table 415.
TEST #228 MTP Manager I Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1000
ABORT
The system software resources required for this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2033
2034
ABORT
Internal system error
Port busy
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page