PE-BCHL (PRI Endpoint Port)
Issue 5 October 2002
1453
555-233-119
Table 386.
TEST #257 Call State Audit Test
Error
Code
Test
Result
Description/Recommendation
1019
ABORT
An audit is already in progress.
1. Wait two minutes and try again.
1113
ABORT
The signaling link has failed. As a result, the system cannot send any
messages on behalf of this port.
1. Check the results of Test #255 (Signaling Link State Check).
1116
ABORT
The port is in an out-of-service ISDN service state.
1. A call cannot be present if the port is in an ISDN out-of-service state.
As a result, a call state audit would be inappropriate, and no action is
necessary. (Use the status pri-endpoint <extension> command to
investigate the ISDN state of the port).
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
To complete the test on this port, do one of the following:
1. Re-attach the disconnected PRI terminal adapter, or
2. Disable the rollabout video feature on this circuit pack by entering the
change ds1 PCSS command, and set the field “Alarm when PRI
Endpoint Detached?” to “y.”
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS
This switch sent a call state auditing message to the far-end terminal
adapter to verify the state of the call active on this port. If a call state
mismatch is found, the call is torn down within two minutes. If no call was
active, no message was sent.
Continued on next page