Maintenance Objects
555-233-119
676
Issue 5 October 2002
Error log entries and test to clear values
Table 3-1.
Analog line error log entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(
a
)
40960
40975
40977
none
15(
b
)
Any
Audits and
Updates Test
(#36)
18
0
busy station
extension
WRN
ON
release station
extension
130(
c
)
None
WRN
ON
test port UUCSSpp sh
257(
d
)
40973
none
513(
e
)
Station
Present Test
(#48)
WRN
OFF
test port UUCSSpp sh r 2
769
Battery Feed
Test (#35)
MIN/
WRN
2
2.
Minor alarms on this MO may be downgraded to Warnings based on the values in set options.
ON
test port UUCSSpp sh r 2
1025
Looparound
Test (#161)
MIN/
WRN
2
ON
test port UUCSSpp l r 2
1281
Conference
Test (#7)
MIN/
WRN
2
ON
test port UUCSSpp l r 2
1537
NPE
Crosstalk
Test (#6)
MIN/
WRN
2
ON
test port UUCSSpp l r 2