Maintenance Commands
555-233-119
528
Issue 5 October 2002
!
WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Feature Interactions
Two users may try to test the same physical hardware (for example, one may use
test alarms and the other may use test board). If test alarms tries to test a board
that is being tested by another user, an error message appears.
Options form
Enter test alarms to display the options screen for alarm.
Field descriptions (Hardware Test Alarm Query)
Alarm Types
The type of alarm to be tested. Enter y/n to select alarms.
Interval
Tests alarms for the last hour (h), last day (d), last week (w) or all
(a).
test alarms repeat 1
HARDWARE TEST ALARM QUERY
The following options control which alarms will be tested.
ALARM TYPES
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): __/__