ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
663
555-233-119
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery, and trying to detect a current.
Table 46. TEST #35 Battery Feed Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the station
extension. Use status station to determine the service state of the port. If
the service state indicates that the port is in use, the port is unavailable for
certain tests. (Refer to the “Status Commands” section in Chapter 8,
“Maintenance Commands and Trouble-Clearing Aids”, for a full description
of all possible states.) Wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1004
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the station
extension. Use status station to determine the service state of the port. If
the service state indicates that the port is in use, the port is unavailable for
certain tests. (Refer to the “Status Commands” section in Chapter 8,
“Maintenance Commands and Trouble-Clearing Aids”, for a full description
of all possible states.) Wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13, 14 and 15
— TN769 vintages 3, 4 and 5
Continued on next page