Table 112.
TEST #619 BRI Port Local TDM Loop Around
Error
Code
Test
Result
Description/ Recommendation
1000
ABORT
The system resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command to
determine the station extension or trunk group/member number of the port.
Use the status bri-port PCSSpp command to determine the service state
of the port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. Wait until the port is idle before retesting.
1. If the port is idle, retry the command at 1-minute intervals a maximum
of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
Continued on next page
Tone
Generator
Tone
Detector
BRI Line
Board
TDM Bus