test alarms
Issue 5 October 2002
529
555-233-119
Output
The following example shows the output from test alarms (query screen left
empty by pressing
ENTER
). The responses appear on a test-by-test basis with one
line of data for each test result.
From
Test alarm from the specified time specified (mm/dd/hh/mm). If no
from
date is entered, then no checking is done and the alarms
active since a month prior to the current time are reported.
To
Test alarms associated with records to the specified time specified
(mm/dd/hh/mm). If no
to
date is entered, any alarm active after the
from
date is selected.
Equipment
Type
If these fields are blank, the system defaults to all of the equipment.
Select one of the following fields:
■
Cabinet
: tests alarms associated with a particular cabinet (1-3).
■
Port Network
: tests all alarms associated with a particular port
network (1-3).
■
Board Number
: tests all alarms associated with a particular
circuit pack (PCSS, default cabinet = 1).
■
Port
: tests all alarms associated with a particular port on a
circuit pack (PCSSpp, default cabinet = 1).
■
Category
: Alarms for a particular equipment category
■
Extension
: Alarms associated with an extension number
■
Trunk
(group/member): tests all alarms associated with a
particular trunk group or trunk group member, XX/YY, where the
group identifier tests all alarms associated with a trunk group
(XX/__), and the group identifier and member identifier are both
entered to test all alarms associated with a specific trunk group
member (XX/YY).