555-233-119
1158
Issue 5 October 2002
Table 250.
TEST #13 Voice and Control Channel Local Loop Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the
station extension or attendant number of the port. Use status station or
status attendant to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. Wait until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system is under
heavy traffic conditions or it has time slots out-of-service due to TDM-BUS
errors. Refer to TDM-BUS to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension or attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page