test processor
Issue 5 October 2002
583
555-233-119
Output
The following output example is for test processor a. The responses appear on a
test-by-test basis with one line of data for each test result.
Field descriptions
Port
The port address (cabinet-carrier)
Maintenance
Name
Maintenance object being tested is MEMORY.
Alt. Name
Not applicable.
Test No.
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
test processor a
SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A PROCR 77 PASS
01A PROCR 80 PASS
01A PROCR 82 PASS
01A PR-MAINT 102 ABORT 1018
01A PR-MAINT 103 ABORT 1018
01A PR-MAINT 106 PASS
01A PR-MAINT 228 PASS
01A PR-MAINT 229 ABORT 1018
01A MEMORY 87 PASS
01A MEMORY 631 PASS