Maintenance Objects
555-233-119
652
Issue 5 October 2002
FAIL
The terminal equipment is not connected to the circuit pack. Some terminal
equipment, such as modems, may fail even when connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to “RING-GEN”.
3. Check all of the wiring between the station equipment and the switch,
and run the test again.
4. If the test still fails, the set may be defective. Check the set, and replace
it, if necessary.
5. Some terminal equipment could fail even when it is connected properly.
If this is the case, use change station extension and enter n in the
Test
field to disable the test. Note that this action also disables tests 6,
7, 161, and 35 on this port.
PASS
The station is connected properly to the switch. This test may also pass if no
terminal equipment is connected and the terminal is located very far from the
switch. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config,
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between the
internal ID and the port. If this is not the case, check to ensure that there
is a valid board inserted.
Table 42. TEST #48 Station Present Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page