
Maintenance Objects
1780
Issue 5 October 2002
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
Table 528.
TEST #53 SAKI Sanity Test
Error
Code
Test
Result
Description/ Recommendation
None
ABORT
System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1005
ABORT
Wrong circuit pack configuration to run this test. This error applies only to
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is
providing timing for the system, and therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to another
DS1 Interface circuit pack or to the Tone-Clock circuit pack and try again.
Refer to
‘‘SYNC (Synchronization)’’
Maintenance documentation.
1015
ABORT
Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute the reset board command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute the reset board command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the Short Test Sequence.
Continued on next page