CLAN-BD (Control LAN Circuit Pack)
Issue 5 October 2002
877
555-233-119
Notes:
a. Error Type 1: Circuit pack stopped functioning or is not physically present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (reset board
UUCSS).
3. If the error persists, replace the circuit pack.
b. Error Type 18: The CLAN circuit pack busied out.
c. Error Type 217: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257: Transient communication problem between switch and
circuit pack; does not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop Test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop Test indicate circuit pack
hardware failure.