DID-TRK (DID Trunk)
Issue 5 October 2002
1007
555-233-119
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension, attendant number, or trunk group/member
number of the port. Use the status station, status attendant, or status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting. Attendants are
always in use (off-hook) if the handset is plugged in and the port is not
busied out.
1. If the port status is active but the port is not in use (no calls), check the
Error Log for Error Type 513 (see Error Log table for description of this
error and required actions). The port may be locked up.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension, attendant number, or trunk group/member number of the port.
Use the status station, status attendant, or status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use
(off-hook), if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
Test disabled via administration. Verify that the “Maintenance Tests?” field
on the Trunk Group Form is set to “n.” To enable the test, issue the change
trunk-group x command where “x” equals the number of the trunk group to
be tested. Then change the entry in the “Maintenance Tests?” field on the
form to “y.”
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2100
ABORT
System resources required to run this test are not available. This may be
due to the port being seized.
1. This abort code is usually associated with tone-clock (TONE-BD,
TONE-PT, and TDM-CLK) resources. First, clear any tone errors in the
error log.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 190.
TEST #33 Looparound and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page