Maintenance Commands
555-233-119
596
Issue 5 October 2002
test tone-clock
Use test tone-clock to run hardware diagnostic tests on a tone or clock circuit
pack.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
tone-clock
location
short
long
repeat
number
clear
schedule
PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Use the screen to schedule execution of
the command. The command is placed
in the command queue and is executed
at the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence
= short;
Repeat =
1
none