Maintenance for CSI systems
555-233-119
68
Issue 5 October 2002
Power Up the AUDIX System
If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatically.
2. Check for SUCIX System errors.
If the AUDIX remained in the cabinet, but power was removed from the cabinet:
1. Power up the cabinet. The AUDIX reboots automatically.
2. Check for AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet was not powered down:
1. At the AUDIX console, hold the
crtl
key down and enter cc.
2. Enter 5 at the prompt. In about 2 minuted the AUDIX boots up.
3. When the system initialization is complete, log in as craft.
4. Check for AUDIX System errors.
Replacing the Power Supply
1. Pull on the latch for the 650A Power Supply.
2. Replace the power supply and secure the latch.