Maintenance for CSI systems
555-233-119
110
Issue 5 October 2002
LED Interpretation
The lighting and unlighting of LEDs indicates to the system user the status of
various maintenance components in the system. LEDS are located on the
attendant console, on all circuit packs in the switch cabinets and, optionally, on
customer-designated voice terminals. The following LEDS are included in the
system:
■
‘‘TN2402/TN798 Processor Circuit Pack LEDs’’
■
‘‘Attendant Console LEDs’’
■
‘‘Control and Port Circuit Pack Status LEDs’’
■
‘‘Power Supply LEDs’’
Terminal Alarm Notification
Terminal Alarm Notification lists several types of alarms on voice terminals with
administered feature buttons or the attendant console. A maximum of ten digital
and/or hybrid voice terminals may be used.
When an alarm occurs, the green status LED associated with the assigned button
will be in a steady state. The lamp may be turned off by pressing the button
associated with the lighted alarm lamp. If the lamp is turned off, and the alarm has
not been resolved by the time maintenance reschedules testing, the green status
LED will resume its steady state. The following alarms appear:
ac-alarm
Administered Connection Alarm: a locally administered
connection (ADM-CONN) has a Major, Minor, or Warning
alarm active.
pr-awu-alm
Auto Wakeup Journal Printer Alarm: the automatic wakeup
journal printer has a Major, Minor, or Warning alarm active.
off-bd-alarm
DS1 or ATM Facility Alarm: an off-board Major, Minor, or
Warning alarm is active on a DS1-BD, UDS1-BD, or
ATM-TRK board.
trk-ac-alm
Facility Access Alarm: The facility access trunk test feature
is activated.
major-alrm
Major Alarm: The system has logged a Major Alarm.
mj/mn-alrm
Major/Minor Alarm: The system has logged a Major or Minor
Alarm.
pr-pms-alm
PMS Printer: The Property Management System printer has
a Major, Minor, or Warning alarm active.
rs-alert
Reset-Alert: reset system 2 or 3 has been performed.
cdr1-alrm
Call Detail Recording Alarm: The Primary CDR Link has a
Major, Minor, or Warning alarm active.