Maintenance Commands
555-233-119
172
Issue 5 October 2002
busyout port
Use busyout port to place the specified port on a circuit pack in a maintenance
busy state. No periodic or scheduled tests are performed on the busied out port
until it is released. When the object is maintenance busy, it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type 18)
are generated on each busied out maintenance object, so that INADS can
determine the state of the objects.
Use release port to reactivate the administered port on a circuit pack at a
specified location.
Output
The following example is a display of busyout port.
Field descriptions
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature Interactions
busyout port
location
Port address: PCSS
marked port: PPSSpp
Examples:
busyout port 01c1101
busyout port 02c1501
init
inads
craft
none
see below
Port
Port address (cabinet-carrier-slot-circuit)
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy (xxx=trunk group, yyy=member number)
private CO line
P/xxx (xxx=private CO line group number)
Maintenance Name
Type of busied out maintenance object.
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
busyout port 01C0701
SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C0701 ANL-LINE PASS