AN-LN-PT (Analog Line Port)
Issue 5 October 2002
677
555-233-119
Notes:
a. Error Type 1: these are in-line errors and can only be resolved over time.
■
Aux Data 40960 indicates that too many simultaneous incoming
ringing attempts were made on this board. Only 4 ports on a board
may ring simultaneously. A 5th incoming call will cause an inline
error from the board.
■
Aux Data 40975 indicates that the terminal equipment was on-hook
when ring-tip was detected during ringing. This usually indicates a
failure in the terminal equipment or the type of terminal has a low
ringer impedance.
1. Call the terminal equipment and verify that the terminal rings.
2. If the terminal does not ring, replace it.
3. Otherwise, use test port UUCSSpp, and follow the
procedure for Test #48.
■
40977 indicates that no terminal equipment was connected when
ringing was attempted.
1. Run the short test with test port UUCSSpp, and follow the
procedure for the results of Test #48.
b. Error Type 15: this is a software audit error that does not indicate any
hardware malfunction.
1. Run the Short Test Sequence and investigate any associated errors.
c. Error Type 130: this error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes.
1. To clear the error, reseat or replace the circuit pack.
d. Error Type 257: this is an in-line error and can only be resolved over time.
This error indicates that ringing voltage is absent.
1. If only 1 analog circuit pack in the system has this problem, replace
the circuit pack.
2. If only analog circuit packs on a particular carrier have this error, the
ringing generator may not be connected to this carrier.
3. If analog circuit packs on many carriers have this error, it is probably
a problem with the ringing generator.
e. Error Type 513:Test #48 can cause some terminal equipment to ring
briefly during daily maintenance.
1. If this disturbs the user or the phone equipment, to disable Test #48
use change station
extension
and set the
Tests
field to n. On
some software releases, this will also disable Tests #6, 7, 35, 47,
and 161.